The rated firewall must extend from the foundation to underneath the roof sheathing and must also run the full length of the building along the lot line.
Residential party wall construction roof sheathing ridge.
Exterior walls of wood frame construction shall be designed and constructed in accordance with the provisions of this chapter and figures r602 3 1 and r602 3 2 or in accordance with awc nds.
Portland cement plaster on studs spaced 16 inches.
Wall sheathing shall be fastened directly to framing members and where placed on the exterior side.
Components of exterior walls shall be fastened in accordance with tables r602 3 1 through r602 3 4.
Parapets constructed in accordance with section r302 2 3 shall be constructed for townhouses as an extension of exterior walls or common walls in accordance with the following.
So companies like norbord started creating tallwall windstorm panels to help alleviate this.
This module also provides for alternate 24 inch spacing of floor wall and roof fram ing where floor and roof trusses are used and accommodates 24 inch spacing of studs where wind loads.
Documents referenced in this.
Section for single story residential construction.
In fact any walls on a house within 5 feet of the lot line except those oriented perpendicular to the lot line must have a.
The death of the 8 sheet one of the biggest items when sheathing a wall vertically is that the sheathing has to be continuous 602 10 4 5 which meant that an 8 sheet wouldn t cut it in many places so longer ones were required.
Sheathing deck or slab the space between the ceiling and the sheathing deck or slab above shall be fireblockedor draftstoppedin accordance with section 718 2 and 718 3 at the partition line.
Detail a illustrates a typical roof ridge connection when using rafters and ceiling joists.
This includes any walls that extend past an adjacent unit due to an offset in the building layout.
Particleboard wall sheathing panels where installed in accordance with table 2308 9 3 6.
One or more.
2015 seattle residential code 399 chapter 8 roof ceiling construction section r801 general r801 1 application.
Where roof surfaces adjacent to the wall or walls are at.
Roof and ceiling construction shall be capable of accommodating all loads imposed in accor.
And panel sheathing products.
Building inspectors and students in the building trades.
Roof shingling may start at your own risk however this inspection must be obtained prior to completing shingle installation and flashing must be visible if not inspected at the 63 roof wall sheathing.
Do not install shingles if felt was damaged at the 63 roof wall sheathing inspection.