It can be nailed temporarily to each truss as the next truss is put in place.
Reinforce roof with trusses and rafter ties.
For hip roofs the code specifies that hip and girder rafters or trusses be connected to exterior wall plates.
Notice the rafter spreader bolt.
The ceiling joists create a truss to begin with i m suggesting adding another member to the truss.
High enough to give room to nail the mid span cross tie at the desired location.
When the ceiling joists are running perpendicular with the rafters then rafter ties are run above the joists in the direction of the rafters and are fastened to them.
In most homes the ceiling joists also serve as the rafter ties.
To hold them up until the decking of the roof is placed on top a 12 foot 1 inch by 4 inch piece of lumber is used.
Reinforce your roof a properly constructed roof in areas subject to high winds has trusses attached to walls with hurricane tiedowns properly nailed sheathing and heavy duty shingles.
Collar ties rafter ties tension beams structural ridge beams.
Ceiling joists can serve as rafter ties when they are running the same direction as the rafters and are properly tied tied together with them at the exterior wall.
Some of these can support the roof and prevent ridge sagging and wall spreading.
A lack of rafter ties is a serious structural issue in a conventionally framed roof.
With the roof rafter pair straightened clamp new mid span cross ties in place and then nail the tie ends to the rafters.
As the rafter tie is raised it puts a bending load on the rafter at the point of connection the rafter needs to be deeper as the tie is raised.
Tie to roof rafters at peak tie to ceiling joists roof rafters to ceiling joists at the eaves.
When all the trusses are installed and the first row of decking is on this brace is removed.
For 16 inch on center framing that means connecting four trusses at each end of the house.
Instead of attaching the tie to the rafter you will be attaching it to the bottom chord of the truss.
Consult your local code officials for details.
Rafter ties are always required unless the roof has a structural self supporting ridge or is built using engineered trusses.
This is a picture of another way of framing a roof a heavy timber truss at very wide spacing.
These are usually accomplished during a complete re roofing.
For gable end roofs the florida code requires that you start by tying down roof framing members within 6 feet of each corner.
This scheme is predicated on achieving serious load carrying connections well thought out and installed a 35 or l clips should to it at all joints.
Usually trusses are put 24 inches apart.